Page 44
Aries Spas • User Manual
Appendix A
Special Programming
Setting a Customized Circulation Mode
YourAriesSpaisfactory-settorunforapproximately12hoursperday(6
hoursonthen6hoursoffforeach12hourinterval).
Beforeyouchangethissetting,itiswisetounderstandhowtheInternal
Timeclockworks.Each24hourperiodisbrokenintointervals.Atthe
factoryweset2intervalsof12hourseachintoyourequipment.Wepro-
gramthespatorunfor6hoursineachinterval,totaling12hoursperday.
Beforebeginningtoprogramyourspaequipment,rstdecidehowlong
ineach24hourperiodyouwouldlikeyourspatocirculate.Thendecide
inhowmanyintervalsyouwanttodivideyour24hours.Youcandivide
your24hoursintoasmanyas4intervals(whichwouldbe6hourslong
each).IneachintervaltheAutomaticPurgeCyclewillrunfor1minute.
If,forexample,youdecidedyouwantyourspatorunfor16hoursper
day,butat4differentintervals,thespawouldcirculatefor4hoursthen
beidleforthenext2,onagainfor4,offfor2,onfor4,offfor2.
Tobeginprogramming,dothefollowing:
1. PushandholdtheLightbuttonforabout5seconds,untilthedigital
readoutreads“d”(duration)followedby1or2numbers.Releasethe
lightbutton.The2numbersfollowingthe“d”representhowmany
hoursperintervalthespaissettocirculate.Usetheupordown
arrowsuntilthenumberrepresentsthehoursyouwantthespatocir-
culate.(0wouldbenocirculation,24wouldcirculatecontinuously.)
(Factorysettingis6in2intervals).
2. PresstheLightbuttonagain.Itshouldnowread“F”(frequency)fol-