Page 38
Aries Spas • User Manual
Blowerwillrestartandrunforanadditional30minutes,beforeagain
shuttingoffautomatically.
One of the Bottom Suction Fittings in the footwell area isn’t working
The suction is a suction for the circulating pump
Yourspashouldhave3ormoreBottomSuctions.Oneoftheseisused
toreturnwatertotheCirculatingPump,theothersreturnwatertothe
JetPumps.TheJetPumpsarelargepumpsthatmoveagreatdealof
waterandthepullfromtheirsuctionsisverynoticeable.TheCirculat-
ingPumpisverysmall(forenergyefciency)andmoveswaterata
muchslowerpace.Youwillnotbeabletoseeorfeelthepullofits
bottomsuction,butwillbeabletoseethewaterreturningtothespavia
theCirculation&OzoneJet
The Top Skimmer is not drawing everything in
This is normal and takes no action on your part.
Yourspa’sCirculatingPumpmovessmallvolumesofwateroverlong
periodsoftimeforefciency.Eventually,thesurfaceitemsaredrawn
intothelter.
Nothing works except Circulation Pump and Light
The system has been incorrectly wired and is only
receiving 110 power, instead of 220.
Callyourelectrician,orcallAriesServiceDepartmentforproperwir-
inginstructions.
Air Blower does not work
Air Blower Pump’s automatic shut-off feature has kicked
in.
Thepumpisdesignedtoautomaticallyshutoffafter30minuteruntime
topreventoverheatingifusershouldforgettoturnoff.Waitaminute,
thenreactivateblower.
Air Blower Pump’s Internal High Limit has been tripped.
Thepumphasbecomeoverheated.Theinternalswitchwillresetitself
aftertheunithascooledsufciently.Wait20minutesorsoandtryto
turnonagain.